G1320
The product is widely used for testing various parameters of high-frequency electronic transformers, inductors, coils, capacitors, resistors, magnetic materials and other components
Category:
Keywords: electronic testing instruments
MESSAGEProduct Details
G1320 DC overlapping current source
Introduction
GKT1320 series DC overlapping current source can control current output through 3300 series LCR. Wide test specification environment requirements, up to 100A DC overlap, meeting RD.DC.QA.
Main features and performance
■ Positive and negative current switching function.
■ Frequency response 20Hz-1MHz
■0.001A-20.00A,150W。 Can be amplified to 100Adc
■ 16 * 2 LCD text display
■ 50 sets of internal instrument settings can be stored and called
■ 0.001 Ω - 199.99 Ω DCR measurement function
■ Single-point current timing test (24 hours)
■ Long-term continuous maximum power output function
■ Automatic or manual trigger bias current scanning frequency (2-11 points) power supply inductor core characteristic analysis
■ Long-term continuous maximum power output function
■ Better circuit protection to prevent LCR meter from being damaged due to abnormal bias current
General specifications
| temperature humidity | Temperature: 0-40 ℃, humidity: C, £ 90% RH | |
| Power requirements | Voltage | 90Vac-125Vac or 190Vac-250Vac |
| frequency | 48Hz-62Hz | |
| Power consumption | ≤650 VA | |
| Dimensions (W×H×D) | 445W x 175H x 425D mm | |
| weight | About 13.5kg | |
technical parameter
|
Model |
1320 DC overlapping current source |
|
Output current |
0.00-20.00Adc forward/reverse, can be amplified to 100Adc in 1720s |
|
Accuracy |
0.000A-1.000A:1%+3mA 1.001A-5.00A:2% |
|
Scan test |
Manual or automatic, 2-11 steps |
|
Response frequency |
20Hz-1MHz |
|
Max output time |
>24小时(40℃) |
|
Timing |
0-24 hours |
|
Delay time |
0.0-100.0sec/step,adjustable |
|
DC Resistance Accuracy |
|
|
DC resistance 20mΩ |
2%+0.07mΩ,0.01mΩ |
|
DC resistance 200mΩ |
2%+0.2mΩ,0.01mΩ |
|
DC resistance 2Ω |
3%+0.002Ω,0.001Ω |
|
DC resistance 20Ω |
3%+0.002Ω,0.01Ω |
|
DC resistance 200Ω |
3%+0.2Ω,0.01Ω |
|
DC Voltage Display |
|
|
Display range |
0.00V-10.00Vdc |
|
Accuracy |
2%+0.05Vdc |
|
Display |
16*2text dot matrix LCD |
G1320S DC overlapping current source
Main features and performance
■ Positive and negative current switching function
■ Frequency response 20Hz-1MHz
■ It can be expanded to 100Adc with 1320 host
■ Power 600VAmax
brief introduction
GKT1320S DC overlapping current source can be superimposed with GKT1320, and the current output is controlled by 3300 series LCR,. Wide test specification environment requirements, up to 100A DC overlap, meeting different applications such as RD.DC.QA
General specifications
|
General specification |
|
|
work environment |
10-40,10%-90%RH |
|
Consumption power value |
600VA max |
|
Power demand |
90Vac-125Vac or 190Vac-250Vac, 48Hz-62Hz |
|
Dimension mm (width * height * depth)Dimension mm |
445*175*425 |
|
weight |
12.5Kg |
technical parameter
|
Model |
1320SDC overlapping current source |
|
Output current |
0.00-20.00Adc(Slave)Forward/reverse(Note2) |
|
Accuracy |
3% |
|
Scan test |
N/A |
|
Response frequency |
20Hz-1MHz |
|
Max output time |
>24小时(40℃) |
|
Timing |
N/A |
|
Delay time |
N/A |
|
DC Resistance Accuracy |
|
|
DC resistance 20mΩ |
N/A |
|
DC resistance 200mΩ |
N/A |
|
DC resistance 2Ω |
N/A |
|
DC resistance 20Ω |
N/A |
|
DC resistance 200Ω |
N/A |
|
DC Voltage Display |
|
|
Display range |
N/A |
|
Accuracy |
N/A |
|
Display |
N/A |
ordering information
GKT1320 current superimposer (main)
GKT1320S current superposition instrument (superposition, cannot be used separately)
Instrument accessories
Connecting line
20A test line
Performance characteristics
4.3 inch color screen display,
Test frequency: 50Hz to 200KHz, any setting (2818A only)
Test frequency: 50Hz to 200KHz, with 37 fixed frequency points (2818B) available for selection
Test level 10mV~2V, 10mV step by step (when the internal resistance is 10 Ω, the highest set voltage is 1V)
Basic accuracy 0.05%
High speed and efficient measurement: up to 32 times/second
Load correction: Calculate and correct the required test data based on specific samples and parameter instruments.
Comparator function: After setting one or more range values of product measurement project parameters, the instrument can compare the obtained measurement values with the set values to determine whether it is a qualified or defective product.
Real time recording of measurement results, accompanied by relevant information such as measurement date, product measurement data file name, and statistics of the number of measurements per day, ensures that the on/off data is not lost
File management function: can store 100 sets of product testing data
Sorting function: subdivide the product into levels, and cooperate with the control mechanical sorting system to sort and classify the products.
V, I test signal level monitoring function
■ Can scan and measure up to 8 frequencies or 8 voltages, while displaying measurement results
Communication interface: RS232C/HANDLER
Previous
Next
Related Products
*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible