PRODUCTS

PRODUCTS

PRODUCTS CENTER


Algeria G3819

Category:

AlgeriaWinding component tester

Product Description

brief introduction

ModelGKT3819 is a new, practical and cost-effective transformer testing system launched by the company according to the current customer production requirements and transformer characteristics testing requirements. The measurement speed is fast, the system stability and reliability are greatly improved, providing the most complete test function for the production line, QC and laboratory. It adopts the guided Chinese menu, with simple and friendly interface, convenient and fast operation, and greatly meets the different test needs of users. The internal storage and memory function of data setting can reach 500 groups, and the external USB flash disk can store unlimited data. At the same time, the instrument also provides a Handler interface and RS-232C serial communication interface, providing conditions for automatic measurement, remote control and data transmission.

 

 

Performance characteristics

Main features and performance

■ Test parameters: including inductance (L), capacitance (C), AC resistance (R), impedance (Z), DC resistance (DCR), transformer phase (PH), turn-Ratio, leakage inductance (LK), pin short circuit (PS), balance (BL) and other test functions
■ 7-inch 16:9 color LCD display, resolution: 800x480, all test items are displayed on the same screen without turning pages
■ Test frequency: 20Hz-200KHz, accuracy: ± (0.01% ± 0.01Hz)
■ The fastest test speed is 100 times/second, and the test results are stable
■ Basic test accuracy: 0.05% (1kHz/1V rms)
■ Test voltage: 10mV to 2V rms, 10mV per section
■ Open circuit/short circuit/load calibration, flexible transformer deviation deduction method
■ It provides three bias current modes: EXT (external bias current source), INT100mA (built-in 100mA current card) and INT1A (built-in 1A current card)
■ Memory and USB flash disk: with large memory space, it can store up to 500 sets of transformer data, and is equipped with standard USB interface to share and manage transformer data. The test data can be directly imported into the USB flash disk and opened by the computer for viewing or editing.
■ Scanning test: GKT3001A test box can be equipped for scanning test of transformer parameters
■ Standard 232, HANDER interface, fully compatible with automatic test, can be built-in 10P, 20P scanning test, save the use cost, make automatic test more convenient
■ Internal resistance mode: there are five internal resistance modes, which can be switched according to different test requirements to better compare with the instrument data of the superior manufacturer

technical parameter

 

Model

3819

major function

Transformer scan test

                                   Test parameters

Transformer scan test

L、C、R、∣Z∣、Y、△、△%、DCR、Turn-Ratio、LK、DL、PS

Q、D、R、θ

                                 Test signal

Test voltage

Turn

10mV~10V,±10%,10mV/Step

other

10mV~2V,±10%,10mV/Step

Test frequency

 

20Hz-200KHz,±0.01%

Output impedance

 

100Ω、30Ω、50Ω、10/100Ω、10/CC

Measurement display range

L.LK

0.00001μH~9999.99H

C

0.00001pF~999.999mF

Q.D

0.00001~99999

Z.X.R

0.00001Ω~99.9999MΩ

Y

0.01nS~99.9999S

θ

-90.00~+90.00

DCR

0.01mΩ~99.999MΩ

Turn

0.01~99999.99circle(Secondary voltage is less than100Vrms)

Pin-short

11 sets, between pins

Basic accuracy

L.LK.C.Z.X.Y.R.DCR

0.05%(In case of AC parameter 1KHz)

Q.D

0.0005(1KHz)

θ

0.03°(1KHz)

Turn

0.5%(1KHz)

Measurement speed (fastest)

L.LK.C.Z.X.Y.R.D

100meas./sec

DCR

75meas./sec

Turn

30meas./sec

Determination method

monitor

eight hundred × 480-point color LCD

    Correction function

Open/short return to zero, load correction
Memory

500 sets of test data settings, which can be expanded by USB

Equivalent circuit mode

Series connection
trigger

Internal, manual, external

Administration

Password management and defective product locking

General specifications

environment condition

Temperature: 10 ° C~40 ° C, humidity: 10%~90% RH

Power consumption

140VA maximum

Power demand

90V~125Vac&190V~250Vac,48Hz~62Hz

weight About 8Kg
Size (width × high × Deep)

395mm×125mm×380mm

ordering information

GKT3819 transformer comprehensive tester

Test fixture

Four-point test line

36P connecting line

1A built-in bias card

Scanning test box (3001A)