PRODUCTS

PRODUCTS

PRODUCTS CENTER


AG G3829

Category:

AGElectronic Transformer Comprehensive Test System

Product Description

Introduction

ModelGKT3829 uses today's latest embedded microprocessor, with high integration, strong data processing capabilities, fast measurement speed, greatly improved system stability and reliability, and provides the most complete test functions for production lines, quality control QC and laboratories . It uses a guided Chinese menu, a simple and friendly interface, convenient and quick operation, and greatly meets the different testing needs of users. The tester provides upper and lower limit comparison and group testing, selection control of test frequency and test voltage, loading correction, multi-frequency scanning test function, single group scanning test function, multiple group scanning test function through scanning test box, data setting Up to 500 groups of internal storage memory function, unlimited storage of external U disk. At the same time, the instrument also provides Handler interface and RS-232C serial communication interface, which provides conditions for automated measurement, remote control, and data transmission.

 

Performance characteristics

■Main features and performance

■Test parameters: the first test parameters L, C, R, ∣Z∣, Y, △, △%, DCR, Turn-Ratio; the second test parameters Q, D, R, θ

■Sweep test: can be equipped with GKT3001A test box for scanning test of various parameters of the transformer.

■Test frequency: 20Hz-200KHz, the test frequency accuracy is 0.05%.

■Test voltage: 10mV to 2Vrms, each segment is 10mV, voltage accuracy: ±10%.

■Basic test accuracy: ±0.1%

■Display: 7-inch color screen, all test items are displayed on the same screen without turning pages.

■Memory and U Disk: It comes with a large memory space, which can store up to 500 sets of transformer data, and is equipped with a standard USB interface, which is convenient for sharing and managing transformer data. The test data can be directly imported into the U disk, opened with a computer for viewing or editing.

■Internal resistance mode: There are 5 internal resistance modes, which can be switched to different internal resistance modes according to different test requirements, so as to better compare with the instrument data of superior manufacturers.

■Multi-frequency point and multi-voltage point test.

■Instrument password management, defective products locking.

■Standard 232, HANDER interface, fully adapted to automated testing.

 

Specification Table

model 3829
The main function Transformer scan test
Test parameters
Transformer scan test L、C、R、∣Z∣、Y、△、△%、DCR、Turn-Ratio、LK、DL、PS
Q 、 D 、 R 、 θ
Test signal
Test voltage Turn 10mV~10V,±10%,10mV/Step
other 10mV~2V,±10%,10mV/Step
Test frequency   40Hz-200KHz,±0.01%
Output impedance   100Ω、30Ω、50Ω、10/100Ω、10/CC
Measurement display range
L.LK 0.00001μH~9999.99H
C 0.00001pF~999.999mF
Q.D 0.00001~99999
Z.X.R 0.00001Ω ~ 99.9999MΩ
Y 0.01nS~99.9999S
θ -90.00~+90.00
DCR 0.01mΩ ~ 99.999MΩ
Turn 0.01~99999.99 circles (the secondary voltage is less than 100Vrms)
Pin-short 11 groups, between pin and pin
Basic accuracy
L.LK.CZXYRDCR 0.05% (if AC parameter is 1KHz)
Q.D 0.0005(1KHz)
θ 0.03°(1KHz)
Turn 0.5%(1KHz)
Measuring speed (fastest)
L.LK.CZXYRD 100meas./sec
DCR 75meas./sec
Turn 30meas./sec
Judgment method

Monitor

800×480 dot color LCD display

Correction function

Open/Short return to zero, load correction
Memory 500 sets of test data settings, which can be expanded via USB
Equivalent circuit mode Series Parallel
trigger Internal, manual, external
manage Password management, defective product lock
General specifications
Environmental conditions Temperature: 10°C~40°C, humidity: 10%~90%RH
Power consumption 140VA max
Power requirement 90V~125Vac or 190V~250Vac, 48Hz~62Hz
weight About 8Kg
Dimensions (width × height × depth) 390×150×330mm

 

Optional

GKT3829 Transformer Comprehensive Tester

Test Fixture

SM test line

36P connection line

1A built-in bias current card

Scan test box (3001A)

Test line