G9058 AC and DC withstand voltage insulation tester is a low-power economical intelligent safety tester. Small size, light weight, beautiful appearance and easy operation. G9058 series products can be widely used in safety inspection of household appliances, chargers/adapters, winding components, electrical equipment and components.

 

Performance characteristics

■ Output power: AC: 5kV/20mA; DC: 6kV/10mA

■ Insulation resistance test voltage: 0.05kV – 1.0kV Insulation resistance test range: 1MΩ – 50GΩ

■ 4.3 inch TFT-LCD, can display test results completely

■ List scan display, multi-step test results can be displayed on the same screen

■ Current base reset function

■ Fast discharge and arc detection function

■ Human body electric shock protection function (GFI)

■ Arbitrarily set the voltage rise time and test time, and the waiting time can be set arbitrarily for the insulation resistance

■ 100 test steps can be stored, 4 test modes can be combined arbitrarily

■ Standard PLC interface, RS232, USB interface

 

General specifications

temperature humidity

0 ° C - 40 ° C, 90% RH

Power requirements

Voltage

198V - 242V or 99V - 121V

frequency

47.5Hz - 63Hz

Power consumption

≤100 VA

Dimensions (W×H×D)

280mm×100mm×400mm

weight

About 11kg  

 

technical parameter

Instrument model

G9058

Pressure test

Test function

AC / DC / IR

Measurement parameters

AC

0.05kV-5.00kV ± (2% reading + 5 words) (50, 60Hz optional)

DC

0.05kV-6.00kV ± (2% reading + 5 words)

Voltage regulation rate

≤(1.0%+5V) (rated power)

Current test range

AC

G9058:0.000mA – 20.00mA

DC

0uA - 10.00mA

Test accuracy

±(2% of reading + 2 words)

Discharge function

Automatic discharge after the test (DCW)

Insulation resistance test

The output voltage

0.05kV-1kV
± (2.0% of reading + 5 words)

Resistance test range

1 MΩ-50GΩ

Resistance test accuracy

500V-1000V

1 MΩ-1GΩ ± (5% reading + 2 words),
1 GΩ-10GΩ ± (10% reading + 2 words)
10GΩ-50GΩ ± (20% reading + 2 words)

50V - 500V

1 MΩ-1GΩ ± (10% of reading + 2 words)

Discharge function

Automatic discharge after the test

Arc detection

Measuring range

AC

0mA – 15mA

DC

0mA – 10mA

Other functions

Voltage rise time

0.1s – 999.9s

Test time (AC/DC)

0.2s – 999.9s

Voltage waiting time (IR)

0.2s – 999.9s

Time accuracy

±(1%+0.1s)

Memory

Internal 100 groups, external 500 groups

interface

PLC,RS232C ,USB

 

Ordering Information

G9058 AC and DC withstand voltage insulation tester

 

Instrument accessories

High voltage test line