PRODUCTS

PRODUCTS

Liechtenstein G3299A/G3299B

Category:

LiechtensteinElectronic Transformer Comprehensive Test System

Product Description

Introduction

ModelGKT3299A/B is a new, practical and cost-effective transformer testing system launched by the company based on current customer production needs and transformer characteristic testing requirements. The measurement speed is fast, the system stability and reliability are greatly improved, and the most complete test function is provided for the production line, quality control QC and laboratory. It uses a guided Chinese menu, a simple and friendly interface, convenient and quick operation, and greatly meets the different testing needs of users. There are as many as 300 groups of internal storage and memory functions for data settings, and unlimited storage on an external U disk. At the same time, the instrument also provides Handler interface and RS-232C serial communication interface, which provides conditions for automated measurement, remote control, and data transmission.

 

Performance characteristics

Main features and performance

■Test items: inductance (L), number of turns (TR), stray capacitance (C), leakage inductance (LK), quality factor (Q value), AC resistance (ACR), DC resistance (DCR), short circuit (PS), balance (BL), GKT3001A can be configured to scan each parameter of the transformer.

■Test frequency: 40Hz-200KHz, the test frequency accuracy is 0.01%.

■Test voltage: 10mV-2V

■Test voltage accuracy: ±10%.

■The test speed is fast, the accuracy is high, and the stability is good.

■5.7 inch 320×240 LED display, high resolution.

■Large instrument memory, up to 300 sets of transformer memory (3299A can be copied by U disk).

■Management function: Defective product lock password management (3299A).

■Standard interface, with automated testing.

 

Specification Table

model 3299A/3299B
The main function Transformer scan test
Test parameters
Transformer scan test L、C、R、∣Z∣、Y、△、△%、DCR、Turn-Ratio、LK、DL、PS
Q 、 D 、 R 、 θ
Test signal
Test voltage Turn 10mV~10V,±10%,10mV/Step
other 10mV~2V,±10%,10mV/Step
Test frequency   40Hz-200KHz,±0.01%
Output impedance   100Ω、30Ω、50Ω、10/100Ω、10/CC
Measurement display range
L.LK 0.00001μH~9999.99H
C 0.00001pF~999.999mF
Q.D 0.00001~99999
Z.X.R 0.00001Ω ~ 99.9999MΩ
Y 0.01nS~99.9999S
θ -90.00~+90.00
DCR 0.01mΩ ~ 99.999MΩ
Turn 0.01~99999.99 circles (the secondary voltage is less than 100Vrms)
Pin-short 11 groups, between pin and pin
Basic accuracy
L.LK.CZXYRDCR 0.05% (if AC parameter is 1KHz)
Q.D 0.0005(1KHz)
θ 0.03°(1KHz)
Turn 0.5%(1KHz)
Measuring speed (fastest)
L.LK.CZXYRD 100meas./sec
DCR 75meas./sec
Turn 30meas./sec
Judgment method

Monitor

800×480 dot color LCD display

Correction function

Open/Short return to zero, load correction
Memory 300 sets of test data settings, which can be expanded via USB (3299A only)
Equivalent circuit mode Series Parallel
trigger Internal, manual, external
manage Password management, defective product lock (3299A only)
General specifications
Environmental conditions Temperature: 10°C~40°C, humidity: 10%~90%RH
Power consumption 140VA max
Power requirement 90V~125Vac or 190V~250Vac, 48Hz~62Hz
weight About 8Kg
Dimensions (width × height × depth) 390×150×330mm